871 research outputs found

    Precocious Locomotor Behavior Begins in the Egg: Development of Leg Muscle Patterns for Stepping in the Chick

    Get PDF
    BACKGROUND:The chicken is capable of adaptive locomotor behavior within hours after hatching, yet little is known of the processes leading to this precocious skill. During the final week of incubation, chick embryos produce distinct repetitive limb movements that until recently had not been investigated. In this study we examined the leg muscle patterns at 3 time points as development of these spontaneous movements unfolds to determine if they exhibit attributes of locomotion reported in hatchlings. We also sought to determine whether the deeply flexed posture and movement constraint imposed by the shell wall modulate the muscle patterns. METHODOLOGY/PRINCIPAL FINDINGS:Synchronized electromyograms for leg muscles, force and video were recorded continuously from embryos while in their naturally flexed posture at embryonic day (E) 15, E18 and E20. We tested for effects of leg posture and constraint by removing shell wall anterior to the foot. Results indicated that by E18, burst onset time distinguished leg muscle synergists from antagonists across a 10-fold range in burst frequencies (1-10 Hz), and knee extensors from ankle extensors in patterns comparable to locomotion at hatching. However, burst durations did not scale with step cycle duration in any of the muscles recorded. Despite substantially larger leg movements after shell removal, the knee extensor was the only muscle to vary its activity, and extensor muscles often failed to participate. To further clarify if the repetitive movements are likely locomotor-related, we examined bilateral coordination of ankle muscles during repetitive movements at E20. In all cases ankle muscles exhibited a bias for left/right alternation. CONCLUSIONS/SIGNIFICANCE:Collectively, the findings lead us to conclude that the repetitive leg movements in late stage embryos are locomotor-related and a fundamental link in the establishment of precocious locomotor skill. The potential importance of differences between embryonic and posthatching locomotion is discussed

    Accuracy, Stability, and Corrective Behavior in a Visuomotor Tracking Task: A Preliminary Study

    Get PDF
    Visuomotor tracking tasks have been used to elucidate the underlying mechanisms that allow for the coordination of a movement to an environmental event. The main purpose of the present study was to examine the relationship between accuracy and stability of tracking performance and the amount of corrective movements that emerge for various coordination patterns in a unimanual visuomotor tracking task. Participants (N = 6) produced rhythmic elbow flexion–extension motions and were required to track an external sinusoidal signal at five different relative phases, 0°, 45°, 90°, 135°, and 180°. Differential accuracy and stability were found among the five tracking patterns with the 0° relative phase pattern being the most accurate and stable pattern. Corrective movements were correlated with changes in accuracy only for the 0° relative phase pattern, with more corrections emerging for less accurate performance. The amount of corrective movements decreased as the stability of tracking performance increased for the 0°, 45°, and 135° patterns. For the 90° and 180° tracking patterns, the amount of corrective movements was not correlated with pattern accuracy or pattern stability. The results demonstrate that corrective behaviors are an important motor process in maintaining the stability of stable perception-action coordination patterns, while offering little benefit for unstable perception-action patterns

    Directional interacting whispering gallery modes in coupled dielectric microdisks

    Full text link
    We study the optical interaction in a coupled dielectric microdisks by investigating the splitting of resonance positions of interacting whispering gallery modes (WGMs) and their pattern change, depending on the distance between the microdisks. It is shown that the interaction between the WGMs with odd parity about y-axis becomes appreciable at a distance less than a wavelength and causes directional emissions of the resulting interacting WGMs. The directionality of the interacting WGMs can be understood in terms of an effective boundary deformation in ray dynamical analysis. We also discuss about the oscillation of the splitting when the distance is greater than a wavelength.Comment: 7 pages, 10 figure

    The Effect of Third Party Investigation on Pay-Per-Click Advertising

    Get PDF
    Click fraud is a critical problem in pay-per-click advertising. While both service providers (SPs) and advertisers employ technologies to identify fraudulent clicks, prior work shows that they cannot be induced to make further improvements to their respective technologies. We consider the use of third-party investigation to address this problem and examine whether the responsibility of investigation payments helps induce both parties to work towards improving their technologies unilaterally. Using a principal-agent setting, we show that the advertiser always has incentives to improve his verification technology and the SP will improve his detection technology only when the detection cost is not too large. Given that the cost of detection technology is likely to be small due to the use of inexpensive online filters, our result suggests that third-party investigation helps induce further enhancements to the technologies and is a good mechanism to address the incentive problems in the click fraud setting

    A Clinical Study of the Pulse Wave Characteristics at the Three Pulse Diagnosis Positions of Chon, Gwan and Cheok

    Get PDF
    In this work, we analyze the baseline, signal strength, aortic augmentation index (AIx), radial AIx, time to reflection and P_T2 at Chon, Gwan, and Cheok, which are the three pulse diagnosis positions in Oriental medicine. For the pulse measurement, we used the SphygmoCor apparatus, which has been widely used for the evaluation of the arterial stiffness at the aorta. By two-way repeated measures analysis of variance, we tested two independent measurements for repeatability and investigated their mean differences among Chon, Gwan and Cheok. To characterize further the parameters that were shown to be different between each palpation position, we carried out Duncan's test for the multiple comparisons. The baseline and signal strength were statistically different (P < .05) among Chon, Gwan and Cheok, respectively, which supports the major hypothesis of Oriental medicine that all of the three palpation positions contain different clinical information. On the other hand, aortic AIx and time to reflection were found to be statistically different between Chon and the others, and radial AIx and P_T2 did not show any difference between pulse positions. In the clinical sense, however, the aortic AIx at each palpation position was found to fall within the 90% confidence interval of normal arterial compliance. The results of the multiple comparisons indicate that the parameters of arterial stiffness were independent of the palpation positions. This work is the first attempt to characterize quantitatively the pulse signals at Chon, Gwan and Cheok with some relevant parameters extracted from the SphygmoCor apparatus

    Spin Fluctuation and Persistent Current in a Mesoscopic Ring Coupled to a Quantum Dot

    Full text link
    We investigate the persistent current influenced by the spin fluctuations in a mesoscopic ring weakly coupled to a quantum dot. It is shown that the Kondo effect gives rise to some unusual features of the persistent current in the limit where the charge transfer between two subsystems is suppressed. Various aspects of the crossover from a delocalized to a localized dot limit are discussed in relation with the effect of the coherent response of the Kondo cloud to the Aharonov-Bohm flux.Comment: 4 pages, 2 figure

    Negative Thermal Expansion Coefficient of Graphene Measured by Raman Spectroscopy

    Full text link
    The thermal expansion coefficient (TEC) of single-layer graphene is estimated with temperature-dependent Raman spectroscopy in the temperature range between 200 and 400 K. It is found to be strongly dependent on temperature but remains negative in the whole temperature range, with a room temperature value of -8.0x10^{-6} K^{-1}. The strain caused by the TEC mismatch between graphene and the substrate plays a crucial role in determining the physical properties of graphene, and hence its effect must be accounted for in the interpretation of experimental data taken at cryogenic or elevated temperatures.Comment: 17 pagese, 3 figures, and supporting information (4 pages, 3 figures); Nano Letters, 201

    Magnetic Field Amplification in Galaxy Clusters and its Simulation

    Get PDF
    We review the present theoretical and numerical understanding of magnetic field amplification in cosmic large-scale structure, on length scales of galaxy clusters and beyond. Structure formation drives compression and turbulence, which amplify tiny magnetic seed fields to the microGauss values that are observed in the intracluster medium. This process is intimately connected to the properties of turbulence and the microphysics of the intra-cluster medium. Additional roles are played by merger induced shocks that sweep through the intra-cluster medium and motions induced by sloshing cool cores. The accurate simulation of magnetic field amplification in clusters still poses a serious challenge for simulations of cosmological structure formation. We review the current literature on cosmological simulations that include magnetic fields and outline theoretical as well as numerical challenges.Comment: 60 pages, 19 Figure

    Quantitative Analysis of Peripheral Tissue Perfusion Using Spatiotemporal Molecular Dynamics

    Get PDF
    Background: Accurate measurement of peripheral tissue perfusion is challenging but necessary to diagnose peripheral vascular insufficiency. Because near infrared (NIR) radiation can penetrate relatively deep into tissue, significant attention has been given to intravital NIR fluorescence imaging. Methodology/Principal Findings: We developed a new optical imaging-based strategy for quantitative measurement of peripheral tissue perfusion by time-series analysis of local pharmacokinetics of the NIR fluorophore, indocyanine green (ICG). Time-series NIR fluorescence images were obtained after injecting ICG intravenously in a murine hindlimb ischemia model. Mathematical modeling and computational simulations were used for translating time-series ICG images into quantitative pixel perfusion rates and a perfusion map. We could successfully predict the prognosis of ischemic hindlimbs based on the perfusion profiles obtained immediately after surgery, which were dependent on the preexisting collaterals. This method also reflected increases in perfusion and improvements in prognosis of ischemic hindlimbs induced by treatment with vascular endothelial growth factor and COMP-angiopoietin-1. Conclusions/Significance: We propose that this novel NIR-imaging-based strategy is a powerful tool for biomedical studies related to the evaluation of therapeutic interventions directed at stimulating angiogenesis

    Event-by-event fluctuations in Mean pTp_T and Mean eTe_T in sqrt(s_NN) = 130 GeV Au+Au Collisions

    Full text link
    Distributions of event-by-event fluctuations of the mean transverse momentum and mean transverse energy near mid-rapidity have been measured in Au+Au collisions at sqrt(s_NN) = 130 GeV at RHIC. By comparing the distributions to what is expected for statistically independent particle emission, the magnitude of non-statistical fluctuations in mean transverse momentum is determined to be consistent with zero. Also, no significant non-random fluctuations in mean transverse energy are observed. By constructing a fluctuation model with two event classes that preserve the mean and variance of the semi-inclusive p_T or e_T spectra, we exclude a region of fluctuations in sqrt(s_NN) = 130 GeV Au+Au collisions.Comment: 10 pages, RevTeX 3, 7 figures, 4 tables, 307 authors, submitted to Phys. Rev. C on 22 March 2002. Plain text data tables for the points plotted in figures for this and previous PHENIX publications are (will be made) publicly available at http://www.phenix.bnl.gov/phenix/WWW/run/phenix/papers.htm
    corecore